Foundry Networks LS 624, LS 648 manual Displaying the Temperature on the FastIron LS

Models: LS 648 LS 624

1 76
Download 76 pages 55.7 Kb
Page 44
Image 44
Displaying the Temperature on the FastIron LS

Foundry FastIron LS Layer 2 Compact Switch Hardware Installation Guide

You can use the CLI or Web management interface to do the following:

Display the temperature of the device

Change the warning and shutdown temperature levels

Change the device poll time

NOTE: Fan speed temperature threshold cannot be changed in the first release of the FastIron LS.

Displaying the Temperature on the FastIron LS

By default, the software polls the temperature sensor every 60 seconds to get the current temperature. This poll rate is controlled by the device poll time, which also controls how often the software polls other system components.

To display the temperature of a device, enter the following command at any level of the CLI:

FLS648 Switch> show chassis

Power supply 1 not present

Power supply 2 (NA - AC - Regular) present, status ok

Fan 1 failed

Fan 2 failed

Fan 3 failed

Exhaust Side Temperature Readings:

Current temperature : 31.0 deg-C

Warning level.......: 45.0 deg-C

Shutdown level......: 55.0 deg-C

Intake Side Temperature Readings:

Current temperature : 27.5 deg-C

Boot Prom MAC: 000a.fae1.a189

Syntax: show device

Displaying Syslog Messages for Temperature on the FastIron LS

The software sends a Syslog message and an SNMP trap if the temperature crosses the warning or shutdown thresholds. The following methods describe how to view the system log on the device. If you have configured the device to use a Syslog server or SNMP trap receiver, see the documentation for the server or receiver.

5 - 2

© 2007 Foundry Networks, Inc.

September 2007

Page 44
Image 44
Foundry Networks LS 624, LS 648 manual Displaying the Temperature on the FastIron LS