Frymaster 8196339 operation manual Converting to another Gas Type

Models: 8196339

1 66
Download 66 pages 24.9 Kb
Page 16
Image 16
2.5Converting to another Gas Type

2.5Converting to another Gas Type

Manual background DANGER

This appliance was configured at the factory for a specific type of gas. Converting from one type of gas to another requires the installation of specific gas-conversion compo- nents. Conversion instructions are included with conversion kits.

Switching to a different type of gas without installing the proper conversion components may result in fire or explosion. NEVER ATTACH THIS APPLIANCE TO A GAS SUPPLY FOR WHICH IT IS NOT CONFIGURED!

Conversion of this appliance from one type of gas to another should only be performed by qualified, licensed, and authorized installation or service personnel, as defined in Section 1.7 of this manual.

Protector® Series gas fryers manufactured for non-CE countries use different burners for each type gas. The burners in fryers built for Propane gas have a special gray-colored coating on the burner tiles to enable them to withstand the higher caloric value of the Propane gas. Burners designed for use in propane units may be used in natural gas applications, but not vice versa.

Non-CE Gas Conversion Kits

Natural Gas to Propane (LP) Gas

Propane (LP) Gas to Natural Gas

Full Vat: Part Number 826-2527

Full Vat: Part Number 826-2528

Dual Vat: Part Number 826-2529

Dual Vat: Part Number 826-2530

 

 

 

 

Units manufactured for export to CE countries are equipped with “universal” burners that may be used with either Natural (G20, G25) gas or Butane (G30) and Propane (G31) gasses.

CE Gas Conversion Kits for Units with Gas Valve 810-1715

G20 or G25 (Natural) to G30 or G31 Gas:

G30 or G31 to G20 or G25 (Natural) Gas:

Part Number 826-1196

Part Number 826-1197

 

 

 

 

CE GAS CONVERSION INSTRUCTIONS

1.Between G20- and G25-type Natural Gas, adjust the gas pressure at the regulator. (Refer to the CE Standard Burner Manifold Gas Pressure Chart.) Do not change the orifice.

2.Between a 2nd family (G20 or G25) and a 3rd family gas (G30 Butane or G31 Propane):

a.Change the orifices.

b.Adjust the manifold pressure.

3.Remove the old rating plate and return to Frymaster. Affix the new rating plate included with the conversion kit in place of the old rating plate stating the gas has been converted.

4.If the destination language changes, replace the rating plate. Call your local service agency or KES for a label kit. The language of reference will be on the corner of the label.

2-8

Page 16
Image 16
Frymaster 8196339 operation manual Converting to another Gas Type