Frymaster 8196339 Required airflow for the combustion air supply is 2m3/h per kW, CE Standard

Models: 8196339

1 66
Download 66 pages 24.9 Kb
Page 14
Image 14
CE Standard

*For distances of more than 20 feet (6 m) and/or more than 4 fittings or elbows, increase the connection by one pipe size.

The Protector® Series gas fryer has indicated in the table below. NOTE: and category 3P/B, which is 23kW.

received the CE mark for the countries and gas categories The nominal heat input (QN) is 21kW except for AT, DE, LU

CE Approved Gas Categories by Country

COUNTRIES

CATEGORIES

GAS

PRESSURE (MBAR)

 

 

AUSTRIA (AT)

II2H3B/P

G20

20

 

 

G30, G31

50

 

 

 

 

 

 

BELGIUM (BE)

I2E(R)B

G20, G25

20, 25

 

 

I3+

G30, G31

28-30, 37

 

 

 

 

 

DENMARK (DK)

II2H3B/P

G20

20

 

 

G30, G31

30

 

 

 

 

 

 

 

II2Esi3+

G20, G25

20, 25

 

 

FRANCE (FR)

G30, G31

28-30, 37

 

 

 

 

 

II2Esi3P

G20, G25

20, 25

 

 

 

 

 

 

G31

50

 

 

 

 

 

 

FINLAND (FI)

II2H3B/P

G20

20

 

 

G30, G31

30

 

 

 

 

 

 

GERMANY (DE)

II2ELL3B/P

G20, G25

20

 

 

G30, G31

50

 

 

 

 

 

 

I3P

G31

50

 

 

GREECE (GR)

II2H3+

G20

20

 

 

G30, G31

28-30, 37

 

 

 

 

 

 

ITALY (IT)

II2H3+

G20

20

 

 

G30, G31

28-30, 37

 

 

 

 

 

 

IRELAND (IE)

II2H3+

G20

20

 

 

G30, G31

28-30, 37

 

 

 

 

 

 

LUXEMBOURG (LU)

II2E3B/P

G20

20

 

 

G30, G31

50

 

 

 

 

 

 

 

II2L3P

G25

25

 

 

NETHERLANDS (NL)

G31

50

 

 

 

 

 

II2L3B/P

G25

25

 

 

 

 

 

 

G30, G31

30

 

 

 

 

 

 

NORWAY (NO)

I3B/P

G30, G31

30

 

 

PORTUGAL (PT)

II2H3+

G20

20

 

 

G30, G31

28-30, 37

 

 

 

 

 

 

 

II2H3+

G20

20

 

 

SPAIN (ES)

G30, G31

28-30, 37

 

 

 

 

 

II2H3P

G20

20

 

 

 

 

 

 

G31

37, 50

 

 

 

 

 

 

SWEDEN (SE)

II2H3B/P

G20

20

 

 

G30, G31

30

 

 

 

 

 

 

UNITED KINGDOM (UK)

II2H3+

G20

20

 

 

G30, G31

28-30, 37

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CE Standard

Required airflow for the combustion air supply is 2m3/h per kW.

1.Connect the quick-disconnect hose to the fryer quick-disconnect under the fryer and to the building gas line.

NOTE: Some fryers are configured for a rigid connection to the gas supply line. These units are connected to the gas supply line at the rear of the unit.

2-6

Page 14
Image 14
Frymaster 8196339 operation manual Required airflow for the combustion air supply is 2m3/h per kW, CE Standard