7.2.2 Error Messages and Display Problems

PROBLEM

PROBABLE CAUSES

 

CORRECTIVE ACTION

Heat indicator is on

 

 

 

 

 

and blower is

Blown fuse on interface board or

 

Replace fuse.

running, but burner

ignition module.

 

 

 

 

 

will not ignite.

 

 

 

 

 

7.2.2 Error Messages and Display Problems

 

 

 

 

 

 

 

Corrective Action

 

 

Problem

Probable Causes

 

 

CM7 display is in

 

 

 

 

 

wrong temperature

Incorrect display option programmed.

See page 4-16 for instructions.

 

 

scale (Fahrenheit or

 

 

 

 

 

 

 

Celsius).

 

 

Verify that the drain valve is fully

 

 

CM 7 display shows

Open drain valve or problem with

 

 

 

IGNITION

 

closed. If the problem continues

 

 

FAILURE.

latching circuitry.

 

call your FASC.

 

 

 

 

 

This in an indication of a

 

 

CM7 display shows

Frypot temperature is more than

 

malfunction in the temperature

 

 

 

control circuitry, including a

 

 

410ºF (210ºC) or, in CE countries,

 

 

 

hot-hi-1.

 

failure of the high-limit thermostat.

 

 

 

395ºF (202ºC).

 

Shut the fryer down immediately

 

 

 

 

 

 

 

 

 

 

and call your FASC.

 

 

CM 7 display shows

Fryer temp is above setpoint.

 

Ensure setpoint is set correctly. If

 

 

HIGH temp.

 

problem persists call your FASC.

 

 

 

 

 

This display is normal when the

 

 

 

 

 

fryer is first turned on and may

 

 

CM7 display shows

 

 

appear for a short while if a large

 

 

Frypot temperature is between 180°F

 

batch of frozen product is added to

 

 

LOW TEMP.

(82°C) and 315°F (157°C).

 

the frypot. If the display never

 

 

 

 

 

goes out, the fryer is not heating.

 

 

 

 

 

Shut the fryer down and call your

 

 

 

 

 

FASC.

 

 

CM7 display shows

Problem with the temperature

 

Shut the fryer down and call your

 

 

PROBE

measuring circuitry including the

 

FASC.

 

 

FAILURE.

probe.

 

Verify that the drain valves are

 

 

 

 

 

 

 

CM7 display shows

Open drain valve, failed computer,

 

fully closed. Using the ON/OFF

 

 

 

switch, turn the computer OFF and

 

 

IGNITION

failed transformer, open high-limit

 

 

 

 

then ON again. If this does not

 

 

FAILURE.

thermostat.

 

 

 

 

correct the problem, call your

 

 

 

 

 

 

 

 

 

 

FASC.

 

 

CM 7 display shows

Frypot temperature is more than

 

Call your FASC.

 

 

410ºF (210ºC) or, in CE countries,

 

 

 

 

HOT-HI -1.

 

 

 

 

 

395ºF (202ºC).

 

 

 

 

7-3