Frymaster 8196339 operation manual Reinstall the blower shield or shield assembly

Models: 8196339

1 66
Download 66 pages 24.9 Kb
Page 57
Image 57
5.Reinstall the blower shield or shield assembly.

3.Wrap the motor with plastic wrap to prevent water from entering it. Spray degreaser or detergent on the blower wheel and the blower housing. Allow it to soak for five minutes. Rinse the wheel and housing with hot tap water, then dry with a clean cloth (see Figure 3).

Wrap the motor and wires

with plastic wrap or a

plastic bag.

Blower Housing

Blower Wheel

Figure 3

4.Remove the plastic wrap from the blower motor assembly. Reassemble the blower motor assembly and blower housing. Reinstall the blower assembly in the fryer.

5.Reinstall the blower shield or shield assembly.

6.Light the fryer in accordance with the procedure described in Chapter 3, Section 3.2.2.

7.After the burners have been lit for at least 90 seconds, observe the flames through the burner viewing ports located on each side of the combustion air blower (see Figure 4).

Left Viewing

Port is Behind

Motor

(NOTE: Blower shield omitted for clarity.)

Right

Viewing

Port

Figure 4

The air/gas mixture is properly adjusted when the burner manifold pressure is in accordance with the applicable table on page 2-7 and the burners display a bright orange-red glow. If a blue flame is observed, or if there are dark spots on a burner face, the air/gas mixture requires adjustment.

On the side of the blower housing opposite the motor is a plate with one or two locking nuts. Loosen the nut(s) enough to allow the plate to be moved, then adjust the position of the plate to open

6-4