Frymaster 8196345 manual 1.6Cleaning the Gas Valve Vent Tube

Models: 8196345

1 84
Download 84 pages 44.87 Kb
Page 11
Image 11
1.6Cleaning the Gas Valve Vent Tube

1.6Cleaning the Gas Valve Vent Tube

1.Set the fryer power switch and the gas valve to the OFF position.

2.Carefully unscrew the vent tube from the gas valve. NOTE: The vent tube may be straightened for ease of removal.

3.Pass a piece of ordinary binding wire (.052 inch diameter) through the tube to remove any obstruction.

4.Remove the wire and blow through the tube to ensure it is clear.

5.Reinstall the tube and bend it so that the opening is pointing downward.

1.7Checking the Burner Manifold Gas Pressure

1. On non-CE fryers only ensure that the gas valve knob is in the OFF position.

Honeywell

1.7Checking the Burner Manifold Gas Pressure ON

OFF

2. Remove the pressure tap plug from the gas valve assembly.

Pressure Tap Plug

Typical Non-CE

Typical CE Valve

Valve Assembly

Assembly

3.Insert the fitting for a gas pressure-measuring device into the pressure tap hole.

4.On non-CE fryers only, place the gas valve in the ON position.

5.Place the fryer power switch in the ON position. When the burner has lit and burned steadily for at least one minute, compare the gas pressure reading to the pressure for the corresponding gas in the appropriate table on the following page. The tables list the burner manifold gas pressures for each of the gas types that can be used with this equipment.

1-5

Page 11
Image 11
Frymaster 8196345 manual 1.6Cleaning the Gas Valve Vent Tube, 1.7Checking the Burner Manifold Gas Pressure