1.6Cleaning the Gas Valve Vent Tube
1.Set the fryer power switch and the gas valve to the OFF position.
2.Carefully unscrew the vent tube from the gas valve. NOTE: The vent tube may be straightened for ease of removal.
3.Pass a piece of ordinary binding wire (.052 inch diameter) through the tube to remove any obstruction.
4.Remove the wire and blow through the tube to ensure it is clear.
5.Reinstall the tube and bend it so that the opening is pointing downward.
1.7Checking the Burner Manifold Gas Pressure
1. On
Honeywell
ON
OFF
2. Remove the pressure tap plug from the gas valve assembly.
Pressure Tap Plug
Typical | Typical CE Valve |
Valve Assembly | Assembly |
3.Insert the fitting for a gas
4.On
5.Place the fryer power switch in the ON position. When the burner has lit and burned steadily for at least one minute, compare the gas pressure reading to the pressure for the corresponding gas in the appropriate table on the following page. The tables list the burner manifold gas pressures for each of the gas types that can be used with this equipment.