1.12Probe Resistance Chart

relay marking the wires to ease reassembly. Once replaced, reconnect the power. When replacing a filter relay in the transformer, ensure the 24VAC relay (8070012) is used.

1.12Probe Resistance Chart

Probe Resistance Chart

For use with Protector® Series fryers manufactured with Minco Thermistor probes only.

F

OHMS

C

60

1059

16

65

1070

18

70

1080

21

75

1091

24

80

1101

27

85

1112

29

90

1122

32

95

1133

35

100

1143

38

105

1154

41

110

1164

43

115

1174

46

120

1185

49

125

1195

52

F

OHMS

C

130

1204

54

135

1216

57

140

1226

60

145

1237

63

150

1247

66

155

1258

68

160

1268

71

165

1278

74

170

1289

77

175

1299

79

180

1309

82

185

1320

85

190

1330

88

195

1340

91

F

OHMS

C

200

1350

93

205

1361

96

210

1371

99

215

1381

102

220

1391

104

225

1402

107

230

1412

110

235

1422

113

240

1432

116

245

1442

118

250

1453

121

255

1463

124

260

1473

127

265

1483

129

F

OHMS

C

270

1493

132

275

1503

135

280

1514

138

285

1524

141

290

1534

143

295

1544

146

300

1554

149

305

1564

152

310

1574

154

315

1584

157

320

1594

160

325

1604

163

330

1614

166

335

1624

168

F

OHMS

C

340

1634

171

345

1644

174

350

1654

177

355

1664

179

360

1674

182

365

1684

185

370

1694

188

375

1704

191

380

1714

193

385

1724

196

390

1734

199

395

1744

202

400

1754

204

405

1764

207

1.13 ATO (Automatic Top-Off) Service Procedures

The automatic top-off system is activated when the oil level falls below a sensor in the rear of the frypot. The signal is sent to the ATO board to engage the solenoid to the frypot and turn on the ATO pump. The pump draws oil from the JIB (Jug In Box) to a port in the rear of the frypot. Once the oil level has satisfied the sensor, the pump and solenoid turn off.

The ATO board is located inside the box, behind the JIB (see Figure 1). The power for the ATO board is supplied from the transformer box. The power passes through the transformer inside the ATO box to the board.

Figure 1