1.13.3 Replacing the ATO Board or Transformer |
|
Disconnect the fryer from the electrical power |
|
supply. Locate the ATO box (see Figure 1 on |
|
page |
|
Remove the cover to expose the transformer and |
|
ATO board (see Figure 2). Mark and unplug |
|
any wires or harnesses. Replace the defective |
|
component and reattach all wires or harnesses. |
|
Replace the cover. Once replaced, reconnect the |
|
power. Remove and restore power to ALL |
|
computers after power has been restored to the | Figure 2 |
ATO board. |
|
1.13.4 Replacing the ATO Pump or Solenoid |
|
Disconnect the fryer from the electrical power |
|
supply. Locate the ATO pump and solenoid |
|
tree (see Figure 3), behind the ATO box. Mark |
|
and unplug any wires or harnesses. Replace the |
|
defective component and reattach all wires or |
|
harnesses. Once replaced, reconnect the power. |
|
Figure 3
1.14CM7 Computer Service Procedures 1.14.1 CM7 Computer Troubleshooting
Problem | Probable Causes | Corrective Action | ||
No Display on | A. Computer not turned on. | A. Press the ON/OFF switch to | ||
Computer. | turn the computer on. |
| ||
|
| |||
|
| B. If the computer power cord is | ||
|
| not plugged in, the computer | ||
| B. No power to the fryer. | will not | activate. | Verify |
| computer | power | cord is | |
|
| |||
|
| plugged in and that circuit | ||
|
| breaker is not tripped. |
| |
|
| C. Swap the computer with a | ||
| C. Computer has failed. | computer known to be good. If | ||
| computer functions, replace the | |||
|
| |||
|
| computer. |
|
|
| D. Damaged computer wiring | D. Swap with a harness known to | ||
| harness. | be good. If computer | ||
|
| functions, replace the harness. |