Frymaster 8196345 manual hot-hi-1, Hi-Limit, Exit, Melt, low temp, Error Rm, Sdcrd, Problem

Models: 8196345

1 84
Download 84 pages 44.87 Kb
Page 39
Image 39
hot-hi-1.

Problem

Probable Causes

Corrective Action

 

 

 

E. If any component in the power

 

 

supply

system

(including

the

 

E. Power supply component or

transformer

and

interface

 

interface board has failed.

board) fail, power will not be

 

 

supplied to the computer and it

 

 

will not function.

 

 

Computer locks up.

Computer error.

Remove and restore power to the

computer.

 

 

 

 

 

 

 

 

 

 

Heat indicator off

 

 

 

 

 

 

 

upon initial startup.

 

 

 

 

 

 

 

Display shows hi or

Failed computer.

Replace computer.

 

 

 

hot with alarm

 

 

 

 

 

 

 

sounding.

 

 

 

 

 

 

 

CM7 display is in

 

See section 1.14.2 on page 1-35 to

wrong temperature

Incorrect display option programmed.

scale (Fahrenheit or

change temperature scale.

 

Celsius).

 

This in an indication of a

 

 

CM7 display shows

Frypot temperature is more than

malfunction in

the

temperature

410ºF (210ºC) or, in CE countries,

control

circuitry,

including

a

hot-hi-1.

 

395ºF (202ºC).

failure

of

the

high-limit

 

 

thermostat.

 

 

 

 

CM7 display shows

 

This is displayed only during a

Computer in high-limit test mode.

test of the high-limit circuit and

HI-LIMIT.

indicates that the high-limit has

 

 

opened properly.

 

 

 

 

 

 

This display is normal when the

 

 

fryer is first turned on while in the

 

 

melt cycle mode. To bypass the

 

 

melt cycle press and hold a #2

 

 

product button under the LCD

 

 

display until a chirp is heard. The

CM7 display shows

Frypot temperature is between 180°F

alarm will chirp and the computer

displays

EXIT

MELT

low temp.

(82°C) and 315°F (157°C).

alternating with YES NO. Press

 

 

 

 

the #1 YES button to exit melt. It

 

 

may appear for a short while if a

 

 

large batch of frozen product is

 

 

added to the frypot. If the display

 

 

never goes out, the fryer is not

 

 

heating.

 

 

 

 

 

CM7 display shows

 

 

 

 

 

 

 

ERROR RM

Defective SD Card

Replace card with another card.

SDCRD

 

 

 

 

 

 

 

1-33

Page 39
Image 39
Frymaster 8196345 hot-hi-1, Hi-Limit, Exit, Melt, low temp, Error Rm, Sdcrd, Problem, Probable Causes, Corrective Action