4.It is recommended that the burner gas pressure be checked at this time by the local gas company or an authorized service agent. Refer to “Check Burner Pressure” in Chapter 4 of this manual for the proper procedure. The accompanying tables list the burner gas pressures for the various gas types that can be used with this equipment.
CE Standard for
Burner Gas Pressure
Gas | Pressure | |
Natural Lacq | 7 mbar | |
(G20) under 20 mbar | ||
| ||
Natural Gronique* | 12 mbar | |
(G25) under 25 mbar | ||
| ||
Propane | 22,2 mbar | |
(G31) under 37 mbar | ||
| ||
* Belgian G25 = 7,0 mbar |
| |
|
| |
|
|
Burner Gas Pressure
| Gas | Pressure |
|
|
|
| 3.5" WC |
|
|
| Natural | 0.87 kPa |
|
|
|
| 8.718 mbar |
|
|
|
| 8.25" WC |
|
|
| Propane | 2.05 kPa |
|
|
|
| 20.55 mbar |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2.5Converting to Another Gas Type
DANGER
Your cooker is configured at the factory for a specific type of gas. If you desire to switch from one type of gas to another, specific
Switching to a different type of gas without installing the proper conversion components may result in fire or explosion! NEVER attach your cooker to a gas supply for which it is not configured.
Conversion of this appliance from one type of gas to another should only be performed by qualified, licensed, and/or authorized installation or service personnel, as defined in Section 1.7 of this manual.
CE Gas Conversion Components
G20 or G25 (Natural) to G31 Gas: | G31 (Propane) to G20 or G25 Gas: |
Orifice: | Orifice: |
Ignitor Kit: | Ignitor Kit: |
Conversion Rating Label | Conversion Rating Label |
|
|
|
|
Non-CE Gas Conversion Components
Natural Gas to LP (Propane) Gas: | LP (Propane) Gas to Natural Gas: | |
Orifice: | Orifice: | |
Ignitor Kit: | Ignitor Kit: | |
Regulator: | Regulator: | |
Conversion Rating Label | Conversion Rating Label | |
|
|
|
|
|
|