Frymaster GSMS, GBC, GC 2.5Converting to Another Gas Type DANGER, CE Gas Conversion Components

Models: GC GBC GSMS

1 34
Download 34 pages 51.96 Kb
Page 15
Image 15
2.5Converting to Another Gas Type

4.It is recommended that the burner gas pressure be checked at this time by the local gas company or an authorized service agent. Refer to “Check Burner Pressure” in Chapter 4 of this manual for the proper procedure. The accompanying tables list the burner gas pressures for the various gas types that can be used with this equipment.

CE Standard for

Burner Gas Pressure

Gas

Pressure

Natural Lacq

7 mbar

(G20) under 20 mbar

 

Natural Gronique*

12 mbar

(G25) under 25 mbar

 

Propane

22,2 mbar

(G31) under 37 mbar

 

* Belgian G25 = 7,0 mbar

 

 

 

 

 

Non-CE Standard for

Burner Gas Pressure

 

Gas

Pressure

 

 

 

 

3.5" WC

 

 

 

Natural

0.87 kPa

 

 

 

 

8.718 mbar

 

 

 

 

8.25" WC

 

 

 

Propane

2.05 kPa

 

 

 

 

20.55 mbar

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.5Converting to Another Gas Type

CE Gas Conversion Components DANGER

Your cooker is configured at the factory for a specific type of gas. If you desire to switch from one type of gas to another, specific gas-conversion components must be installed.

Switching to a different type of gas without installing the proper conversion components may result in fire or explosion! NEVER attach your cooker to a gas supply for which it is not configured.

Conversion of this appliance from one type of gas to another should only be performed by qualified, licensed, and/or authorized installation or service personnel, as defined in Section 1.7 of this manual.

CE Gas Conversion Components

G20 or G25 (Natural) to G31 Gas:

G31 (Propane) to G20 or G25 Gas:

Orifice: 810-1970 (2 required)

Orifice: 810-0916 (2 required)

Ignitor Kit: 826-1715 (2 required)

Ignitor Kit: 826-1714 (2 required)

Conversion Rating Label 802-2144

Conversion Rating Label 802-2144

 

 

 

 

Non-CE Gas Conversion Components

Natural Gas to LP (Propane) Gas:

LP (Propane) Gas to Natural Gas:

Orifice: 810-0917 (2 required)

Orifice: 810-0916 (2 required)

Ignitor Kit:

826-1715 (2 required)

Ignitor Kit: 826-1714 (2 required)

Regulator:

807-1848 (1 required)

Regulator: 807-1847 (1 required)

Conversion Rating Label 802-2144

Conversion Rating Label 802-2144

 

 

 

 

 

 

2-8

Page 15
Image 15
Frymaster GSMS, GC 2.5Converting to Another Gas Type DANGER, CE Gas Conversion Components, Non-CEGas Conversion Components