Frymaster GSMS, GBC, GC operation manual 4.4Adjusting the Burner Gas Pressure DANGER

Models: GC GBC GSMS

1 34
Download 34 pages 51.96 Kb
Page 24
Image 24
4.4Adjusting the Burner Gas Pressure

TYPICAL NON-CE BLOWER ASSEMBLY

TYPICAL CE BLOWER ASSEMBLY

4.4Adjusting the Burner Gas Pressure

Manual background DANGER

Frymaster recommends that ONLY qualified service personnel perform this task.

1. On Non-CE cookers, ensure that the gas valve knob is in the OFF position.

2. Remove the pressure tap plug from the gas valve assembly.

Pressure Tap Plug

Typical Non-CE Valve Assembly

Typical CE

Valve Assembly

3.Insert the fitting for a gas pressure-measuring device into the pressure tap hole

4.On NON-CE cookers only, place the gas valve in the ON position.

5.Place the power switch in the ON position. When the burner has lit and burned steadily for at least one minute, compare the gas pressure reading to the pressure for the corresponding gas in the appropriate table below.

4-4

Page 24
Image 24
Frymaster GSMS, GBC, GC operation manual 4.4Adjusting the Burner Gas Pressure DANGER