Frymaster GSMS, GC Problem, Probable Causes, Corrective Action, Water, Temperature Is, Too Low In

Models: GC GBC GSMS

1 34
Download 34 pages 51.96 Kb
Page 30
Image 30

Problem

Probable Causes

Corrective Action

 

A. Controller out of adjustment.

A. Adjust controller in accordance

 

 

with procedure in Chapter 4.

 

B. Failed controller.

B. Order replacement controller

WATER

Test: If another controller known

from FASC or distributor.

 

TEMPERATURE IS

to be working is available,

 

TOO LOW IN

substitute the working controller

 

SIMMER MODE

for the suspect controller. If the

 

 

unit begins to fill, the controller

 

 

has failed.

 

 

C. Open temperature probe or loose

C. Call FASC.

 

probe wire.

 

BASKET LIFT

A. Lack of lubrication on basket lift

A. Lubricate lifter rods with a

MOVEMENT IS

rods.

lightweight lubricant.

JERKY OR NOISY

 

 

5-4