Frymaster KSCF18G Gas Conversion: Procedures, Gas Supply For Which It Is Not Configured, Danger

Models: KSCF18G

1 91
Download 91 pages 47.21 Kb
Page 22
Image 22
3.7 Gas Conversion: Procedures

KSCF18G COOL ZONE SERIES GAS FRYERS

CHAPTER 3: INSTALLATION INSTRUCTIONS

C. Adjustments for different gases are as follows:

ORIFICE SIZE

 

GAS PRESSURE AT

BURNER

PILOT

GAS TYPE

REGULATOR

(# / MM)

MBAR

INCH W.C.

MARKING

MARKING

 

 

 

 

 

 

 

 

 

 

 

#42 / 2,40

G20

10,0

4,0

Blue

26N

#42 / 2,40

G25

15,0

6,0

Blue

26N

#53 / 1,51

G31

27,0

10,8

Red

16LP

 

 

 

 

 

 

NOTE: Outlet gas pressure must be adjusted strictly within the above requirements 5 to 10 minutes after the appliance is operating. For controls and adjustments, please refer to "gas valve" illustrations on Page 3-10. To adjust the pilot flame, turn the pilot adjustment screw clockwise/counter-clockwise until the desired flame-volume is achieved.

3.7 Gas Conversion: Procedures

GAS SUPPLY FOR WHICH IT IS NOT CONFIGURED! DANGER

This appliance was configured at the factory for a specific type of gas. Converting from one gas type to another requires the installation of specific gas-conversion components.

Switching to a different type of gas without installing the proper conversion

components may result in fire or explosion. NEVER ATTACH THIS APPLIANCE TO A

GAS SUPPLY FOR WHICH IT IS NOT CONFIGURED!

Conversion of this appliance from one type of gas to another should only be

performed by qualified, licensed, and authorized installation or service personnel, as

defined in Section 1.7 of this manual.

See Page 3-10 for gas valve illustrations when performing the following conversions.

When converting from G20 to G25 gas, the following procedures apply:

Equipment replacement is not required.

Adjust orifice gas pressure by turning the gas valve adjustment screw.

Seal the screw, after adjustment.

When converting from G20 (or G25) gas to G31 propane (or vice-versa), the following procedures apply:

Replace gas valve.

Replace burner orifices.

Replace pilot(s).

3-9

Page 22
Image 22