Frymaster KSCF18G manual 7.2Fryer Troubleshooting cont, 7.2.6, Main burner malfunctions

Models: KSCF18G

1 91
Download 91 pages 47.21 Kb
Page 47
Image 47
7.2Fryer Troubleshooting (cont.)

KSCF18G COOL ZONE SERIES GAS FRYERS

CHAPTER 7: TROUBLESHOOTING

7.2Fryer Troubleshooting (cont.)

7.2.6

Main burner malfunctions.

A.Main burner will not ignite; no gas is present at main burner.

1.Check that float switch is not stuck in the "down" position.

2.Check and reset the high-limit switch.

3.The combination gas valve and/or electronic ignition system may be defective; contact an authorized service technician for service.

B.Main burner flames are small and appear lazy; shortening does not come up to temperature quickly. Contact an authorized service technician for service.

C.Fryer will not reach setpoint temperature and/or runs erratically.

1.Incorrect location or adjustment of sensor probe. Contact an authorized service technician for service.

2.Defective temperature sensor. Contact an authorized service technician for service.

D.Fryer shortening temperature cannot be controlled; fryer runs at high-limit temperature. Possible causes are:

1.Defective operating thermostat. Contact an authorized service technician for service.

2.Defective temperature probe. Contact an authorized service technician for service.

7-5