KSCF18G COOL ZONE SERIES GAS FRYERS

CHAPTER 7: TROUBLESHOOTING

7.2 Fryer Troubleshooting (cont.)

7.2.3

 

Actual frypot temperature

 

differs

from

computer

(cont.)

setpoint temperature.

 

 

Frypot Front

 

 

 

 

Temperature

High-Limit

 

 

Probe

Probe

 

 

 

 

Temperature Probe

 

 

 

Probe Bracket

 

 

 

Burner Tube

5.The thermometer temperature should be within ±10°F (±5°C) of the computer display temperature.

Yes: System is maintaining temperature properly.

No: Ensure the probe tip is ⅛" from the top of the burner tubes (see illustration). If the probe adjustment is correct, the computer probe circuit may be faulty. If probe adjustment is incorrect, it will require adjustment.

6.Contact your authorized service agent if any of the following occurs during this test:

a.Computer probe circuit is suspected as faulty.

b.Temperature probe requires adjustment.

c.Computer fails to call for heat during the calibration test.

7-3