KSCF18G COOL ZONE SERIES GAS FRYERS
CHAPTER 7: TROUBLESHOOTING
7.2 Fryer Troubleshooting (cont.)
7.2.3 |
| Actual frypot temperature | |||
| differs | from | computer | ||
(cont.) | |||||
setpoint temperature. | |||||
|
| ||||
Frypot Front |
|
|
|
| |
Temperature |
| ||||
| Probe | Probe |
| ||
|
|
| Temperature Probe | ||
|
|
| Probe Bracket | ||
|
|
| Burner Tube |
5.The thermometer temperature should be within ±10°F (±5°C) of the computer display temperature.
Yes: System is maintaining temperature properly.
No: Ensure the probe tip is ⅛" from the top of the burner tubes (see illustration). If the probe adjustment is correct, the computer probe circuit may be faulty. If probe adjustment is incorrect, it will require adjustment.
6.Contact your authorized service agent if any of the following occurs during this test:
a.Computer probe circuit is suspected as faulty.
b.Temperature probe requires adjustment.
c.Computer fails to call for heat during the calibration test.