3.9 Safety Switches (cont.)

KSCF18G COOL ZONE SERIES GAS FRYERS

CHAPTER 3: INSTALLATION INSTRUCTIONS

3.9 Safety Switches (cont.)

B.Other Fryer/Filter Switches

1.Drain Valve Microswitch: The computer will display DRAIN OPEN when the drain valve is opened. The computer will lockout, preventing any cooking operation until EXIT/COOL FILTER is pressed.

A microswitch is located on the red handle at the drain valve.

2.Float-Switch:Located in the frypot. Designed as a safety switch, it deactivates the gas valve, preventing burner ignition until the oil level extends above the heating tubes.

3.High-limit Reset: Located in the right fryer cabinet under the control panel. This switch is used to reset the high-limit if the cooking medium has reached high temperature safety limits. The high-limit sensor bulb is mounted inside the frypot between the two left-most burner tubes.

4.Manual Filter Override Switch: Also located in the right fryer control panel of the fryer battery. This rocker switch (older units have toggle switches) allows the operator to manually operate the filtration system if a problem develops with the auto filtration functions.

3-12

Frypot Front

High-Limit Float Temperature Probe Switch Probe