KSCF18G COOL ZONE SERIES GAS FRYERS

CHAPTER 3: INSTALLATION INSTRUCTIONS

3.7 Gas Conversion: Procedures (cont.)

When converting from G20 (20 mbar) to G25 (25 mbar), or vice-versa, or G31 (37 mbar) to G31 (50 mbar), the following procedures apply:

Check pilot adjustment and adjust as necessary.

Other adjustments are not necessary.

Conversion from one gas family to another (e.g. changing from natural gas to propane) requires special components and parts. Contact a Factory Authorized Service Agent for requirements and part numbers.

Conversions can only be executed by qualified, factory-authorized personnel.

Pilot flow adjustment

Thermocouple connection

Vent tube connection

 

 

Pressure flow adjustment

OFF Button

ON Button- Pilot Gas-flow

CE Gas Valve

Pilot pressure adjustment

Pressure flow adjustment

(remove cover screw to access)

(remove cover screw to access)

Regulator Vent

Pilot gas supply connection.

ON/OFF Gas-Cock Knob

Non-CE Gas Valve

3-10

Page 23
Image 23
Frymaster KSCF18G manual Non-CE Gas Valve