KSCF18G COOL ZONE SERIES GAS FRYERS
CHAPTER 6: PREVENTATIVE MAINTENANCE
6.3 Periodic/Annual
This appliance should be inspected and adjusted periodically by qualified service personnel as part of a regular kitchen maintenance program.
Frymaster and Dean recommend that a Factory Authorized Service Technician should inspect this appliance at least annually, as follows:
•Inspect the cabinet
•Verify that debris or accumulations of solidified oil or shortening do not obstruct the flue opening.
•Verify that burners and associated components (e.g., gas valves, pilot assemblies, ignitors) are in good condition and functioning properly. Inspect all gas connections for leaks and verify that all connections are properly tightened.
•Verify that the burner manifold pressure matches the pressure specified on the fryer’s rating plate.
•Verify that the temperature and
•Verify that component box components (e.g., computer/controller, transformers, relays, interface boards) are in good condition and free of oil
•Verify that all safety features (e.g., drain safety switches, reset switches) are present and functioning properly.
•Verify that the frypot/cookpot is in good condition and free of leaks and that the frypot/cookpot insulation is in serviceable condition. Verify that the frypot tube diffusers are present and in good condition (i.e. no visible deterioration or damage).
•Verify that wiring harnesses and connections are tight and in good condition.
Built-in Filtration:
•Inspect all
•Inspect the filter pan for leaks and cleanliness. If there is a large accumulation of crumbs in the crumb basket, advise the owner/operator that the crumb basket should be emptied into a fireproof container and cleaned daily.
•Verify that all