To be installed in accordance with AS 5601 / AG 601, local authority, gas, electricity, and any other relevant statutory regulations.

Manual background DANGER

This appliance is equipped with a special (grounding) plug for your protection against electrical shock, and must be plugged directly into a properly grounded re- ceptacle. Do not cut, remove, or otherwise bypass the grounding prong on this plug!

Manual background DANGER

This appliance requires electrical power for operation. Place the gas control valve in the OFF position in case of a prolonged power outage. Do not attempt to operate this appliance during a power outage.

Manual background WARNING

To ensure the safe and efficient operation of the fryer and hood, the electrical plug for the 120-volt line, which powers the hood, must be fully engaged and locked in its pin and sleeve socket.

2.1.4 Australian Requirements

To be installed in accordance with AS 5601 / AG 601, local authority, gas, electricity, and any other relevant statutory regulations.

2.2Caster Installation

Depending upon the specific configuration ordered, your fryer may have been shipped without installed casters. DO NOT INSTALL THIS APPLIANCE WITHOUT CASTERS. If the appliance requires the installation of casters, install them in accordance with the instructions included in your accessory package.

2.3Pre-Connection Preparations

Manual background DANGER

DO NOT connect this appliance to the gas supply before completing each step in this section.

After the fryer has been positioned under the exhaust hood, ensure the following has been accomplished:

1.Adequate means must be provided to limit the movement of fryers without depending upon the gas line connections. If a flexible gas hose is used, a restraining cable must be connected at all times when the fryer is in use. The restraining cable and installation instructions are packed with the flexible hose in the accessories box that was shipped with your unit.

2.Single unit fryers must be stabilized by installing restraining chains on fryers equipped with casters. Follow the instructions in the accessory pack to install the chains.

2-3