Frymaster BIPH55, MPH55 warranty Press the switch twice to display the set point

Models: BIPH55 MPH55

1 44
Download 44 pages 18.36 Kb
Page 31
Image 31
3.Press the  switch twice to display the set point.

Manual background DANGER

Ensure that the frypot is completely free of water before filling with oil or shortening. When the oil or shortening is heated to cooking temperature, water in the frypot will cause splattering.

5.3.3 Clean Filter Pan, Detachable Parts and Accessories

As with the frypot, a deposit of carbonized oil or shortening will accumulate on the filter pan and detachable parts and accessories such as baskets, sediment trays, or fishplates.

Wipe the filter pan and all detachable parts and accessories with a clean dry cloth. Use a cloth dampened with a solution of McDonald’s All Purpose Concentrate to remove accumulated carbonized oil. Rinse and thoroughly dry each part. DO NOT use steel wool or abrasive pads to clean these parts. The scratches that result from such scrubbing make subsequent cleanings more difficult.

5.4MONTHLY CHECKS AND SERVICE

5.4.1 Check M2000 Computer Set Point Accuracy

1.Insert a good-grade thermometer or pyrometer probe into the oil, with the end touching the fryer temperature-sensing probe.

2.When the computer display shows a series of dashes “----” or a product name (indicating that the

frypot contents are within the cooking range), press the Manual background switch once to display the temperature of the oil or shortening as sensed by the temperature probe.

3.Press the Manual background switch twice to display the set point.

4.Note the temperature on the thermometer or pyrometer. Actual temperature and pyrometer readings should be within ± 5ºF (3ºC) of each other. If not, contact a Factory Authorized Service Center for assistance.

5.5QUARTERLY CHECKS AND SERVICE 5.5.1 Clean Combustion Air Blower Assembly

1.Disconnect the blower wiring harness and remove the four blower mounting nuts. (See Figure 1 on next page)

5-3