4.Remove the plastic wrap from the blower motor assembly. Reassemble the blower motor assembly and blower housing. Reinstall the blower assembly in the fryer.
5.Reinstall the blower shield or shield assembly.
6.Light the fryer in accordance with the procedure described in Chapter 3, Section 3.1.
7.After the burners have been lit for at least 90 seconds, observe the flames through the burner viewing ports located on each side of the combustion air blower. (See Figure 4)
Left Viewing
Port is Behind
Motor
(NOTE: Blower shield omitted for clarity.)
Right
Viewing
Port
Figure 4
The air/gas mixture is properly adjusted when the burner manifold pressure is in accordance with the applicable table on page
On the side of the blower housing opposite the motor is a plate with one or two locking nuts. Loosen the nut(s) enough to allow the plate to be moved, then adjust the position of the plate to open or close the air intake opening until a bright
TYPICAL BLOWER ASSEMBLY | SOME CE BLOWER ASSEMBLIES |
| MAY BE CONFIGURED THIS WAY |