PROBLEM | PROBABLE CAUSES | CORRECTIVE ACTION | |
| A. Dirty or obstructed combustion air | A. Clean and adjust per instructions | |
| blower. | in Chapter 5 of this manual. | |
Fryer is operating |
|
| |
normally, but |
|
| |
produces a popping |
|
| |
B. Dirty or obstructed gas valve vent | B. Clean per instructions in Chapter | ||
sound when burners | |||
ignite. | tube | 5 of this manual. | |
|
|
| |
| C. Malfunctioning combustion air | C. If blower is slow to come up to | |
| blower. | speed, contact FASC for service. | |
Computer will not |
|
| |
go into program |
|
| |
mode or some | Failed computer. | Call FASC. | |
buttons do not |
|
| |
actuate. |
|
| |
Heat indicator is on |
|
| |
and blower is | Blown fuse on interface board or | Replace fuse. | |
running, but burner | ignition module. | ||
| |||
will not ignite. |
|
|
6.3Error Messages and Display Problems
Problem | Probable Causes | |
M2000 display is in |
| |
wrong temperature | Incorrect display option programmed. | |
scale (Fahrenheit or | ||
| ||
Celsius). |
|
M2000 display | Fryer is 15ºF (8ºC) above setpoint. | |
shows HI. | ||
|
M2000 display | Frypot temperature is more than | |
410ºF (210ºC) or, in CE countries, | ||
shows HOT. | ||
395ºF (202ºC). | ||
|
Corrective Action
M2000 computers may be programmed to display in either Fahrenheit or Celsius. Refer to the separate M2000 Computer Operation Manual for instructions on changing the display.
This display will appear only if the fryer is in the
This in an indication of a malfunction in the temperature control circuitry, including a failure of the high limit thermostat. Shut the fryer down immediately and call FASC.