Frymaster BIPH55, MPH55 Problem, Probable Causes, Corrective Action, shows LOW TEMP, Failure

Models: BIPH55 MPH55

1 44
Download 44 pages 18.36 Kb
Page 39
Image 39
Problem

Problem

Probable Causes

Corrective Action

 

 

This display is normal when the

 

 

fryer is first turned on and may

M2000 display

 

appear for a short while if a large

Frypot temperature is between 180°F

batch of frozen product is added to

shows LOW TEMP.

(82°C) and 315°F (157°C).

the frypot. If the display never

 

 

goes out, the fryer is not heating.

 

 

Shut the fryer down and call

 

 

FASC.

M2000 display

 

This indicates a problem within the

Problem with the temperature

temperature measuring circuitry

shows PROBE

measuring circuitry including the

that is beyond the scope of

FAILURE.

probe.

operator troubleshooting. Shut the

 

 

fryer down and call FASC.

 

 

This indicates that the fryer is not

 

 

heating. It is displayed if the fryer

 

 

loses its ability to heat oil. It is

M2000 display

 

also displayed when the oil

Open drain valve, failed computer,

temperature is above 450°F

shows IGNITION

failed transformer, open high-limit

(232°C) and the high-limit

FAILURE.

thermostat.

thermostat has opened, halting the

 

 

heating of the oil. Verify that the

 

 

drain valves are fully closed. If

 

 

this does not correct the problem,

 

 

call your FASC.

M2000 display

 

This is displayed only during a test

Computer in hi-limit test mode.

of the hi-limit circuit and indicates

shows HI-LIMIT.

that the hi-limit has opened

 

 

 

properly.

Display shows ,

 

 

heating indicator

 

 

cycles on and off

Failed computer or damaged

 

normally, but

Call FASC.

burners will not

computer wiring harness.

 

light and blower is

 

 

not running.

 

 

 

 

 

Heat indicator off

 

 

upon initial startup.

 

 

Display shows ,

Failed computer, damaged wiring

Call FASC

or with

harness or connector

alarm sounding.

 

 

 

 

 

 

6-4

Page 39
Image 39
Frymaster BIPH55 Problem, Probable Causes, Corrective Action, shows LOW TEMP, Failure, shows IGNITION, shows HI-LIMIT