Image 41

PROBLEM

PROBABLE CAUSES

CORRECTIVE ACTION

 

C. Blockage in filter pump.

C. Pump blockages are usually

 

Test: Close the drain valve. Place the

caused by sediment build-up in

 

the pump due to improperly sized

 

filter handle in the OFF position,

or installed filter pad and failure

 

allow the pump to cool for at least 45

to use the crumb screen. Use a

Continued from

minutes, and then press the reset

thin flexible wire to remove the

button on the pump motor. Pull the

blockage. If the blockage cannot

Previous page

filter pan from the unit. Activate the

be removed, call FASC.

 

 

pump. If the pump motor hums and

Ensure that filter pad is of the proper

 

then stops, the pump is blocked. Also

 

if air or bubbling oil comes out of the

size and is installed properly, and that

 

rear flush port, there is a blockage in

the crumb screen is used.

 

the filter pan suction tube.

 

 

 

A. To properly filter, the oil should

 

 

be at or near 350°F (177°C). At

 

 

temperatures lower than this, the

 

A. Cooking oil is too cold for

oil becomes too thick to pass

 

filtering.

through the filter medium easily,

 

 

resulting in much slower oil

 

 

return and eventual overheating of

Filter Pump starts,

 

the filter pump motor.

B. Improperly installed or prepared

 

but no transfer takes

filter pan components.

B. Remove the oil from the filter pan

place or the oil

 

and replace the filter pad,

return is very slow.

Test: Close the drain valve.

ensuring that the filter screen is in

 

Move the filter handle to the OFF

place under the pad.

 

position, pull the filter pan from

If this does not correct the

 

the unit. Move the filter handle to

 

the ON position.

problem, the filter suction tube is

 

 

probably blocked. Remove the

 

If a strong stream of air is being

blockage using a thin, flexible

 

pumped out of the oil return port,

wire. If unable to remove the

 

the problem is with the filter pan

blockage, call FASC.

 

components.

 