Frymaster MPH55, BIPH55 warranty Problem, Probable Causes, Corrective Action, shows HI 2 BAD

Models: BIPH55 MPH55

1 44
Download 44 pages 18.36 Kb
Page 40
Image 40
shows HI 2 BAD.

Problem

Probable Causes

M2000 display

Computer in hi-limit test mode.

shows HI 2 BAD.

 

 

 

Corrective Action

This is displayed only during a test of the hi-limit circuit and indicates that the hi-limit has failed. DO NOT OPERATE THE FRYER! Call FASC.

6.4Troubleshooting the Built-in Filtration System

PROBLEM

PROBABLE CAUSES

 

CORRECTIVE ACTION

 

A. Thermal overload switch has

A.

If the pump runs normally after

 

tripped on an overheated motor.

 

resetting the thermal overload

 

Test: If the pump stopped

 

switch, the pump was overheated.

 

 

Always filter with the cooking

 

suddenly during the filtering

 

 

process, especially if after several

 

oil/shortening at or near frying

 

filtering cycles, the pump motor

 

temperature.

 

has probably overheated. Place

 

 

Pump won’t start.

the filter handle in the OFF

 

Allow the pump motor to cool off

position, allow the pump to cool

 

for about ten minutes after

OR

for at least 45 minutes, and then

 

filtering two full frypots one after

press the reset button on the pump

 

the other.

Pump stops during

motor. Attempt to activate the

 

Check the filter pad between

pump.

 

filtering.

 

 

filtering. Replace the pad if there

 

 

 

is a large accumulation of

 

 

 

sediment.

 

B. Failed filter handle microswitch.

 

 

 

Test: If this is a multi-pot fryer,

B. If the switch is loose, tighten the

 

attempt to operate the pump using

 

a different handle. If the pump

 

nuts and bolts holding it in place,

 

starts, the handle microswitch is

 

ensuring that when the handle is

 

either out of alignment or has

 

placed in the ON position, the

 

failed.

 

lever on the microswitch is

 

When the handle is placed in the

 

pressed firmly against the switch.

 

 

 

 

ON position, the lever on the

 

If the switch has failed, call

 

microswitch should be firmly

 

FASC.

 

pressed against the switch. If so,

 

 

 

the switch has failed. If not, the

 

 

 

switch is loose and/or misaligned.

 

 

 

 

 

 

6-5