Burner Manifold Gas Pressures
| Gas | Pre s s ure |
|
|
| Natural | 3" W.C. |
|
|
| 0.73 kPa |
|
| |
|
|
|
| |
| Propane | 8.25" W.C. |
|
|
| 2.5 kPa |
|
| |
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
5.Check the programmed temperature thermostat setting. (Refer to the separate M2000 Manual furnished with your unit for the setpoint programming instructions for your particular controller.)
2.5Converting to Another Gas Type
DANGER
This appliance was configured at the factory for a specific type of gas. Converting from one type of gas to another requires the installation of specific
Switching to a different type of gas without installing the proper conversion components may result in fire or explosion. NEVER ATTACH THIS APPLIANCE TO A GAS SUPPLY FOR WHICH IT IS NOT CONFIGURED!
Conversion of this appliance from one type of gas to another should only be performed by qualified, licensed, and authorized installation or service personnel, as defined in Section 1.6 of this manual.
Pro Series H55 gas fryers manufactured for
Natural Gas to Propane (LP) Gas | Propane (LP) Gas to Natural Gas |
Full Vat: Part Number | Full Vat: Part Number |
Dual Vat: Part Number | Dual Vat: Part Number |
|
|
|
|
Units manufactured for export to CE countries are equipped with “universal” burners that may be used with either natural (G20, G25) gas or butane (G30) and propane (G31) gasses.