6.2Troubleshooting Fryers
6.2.1 Computer and Heating Problems
PROBLEM | PROBABLE CAUSES |
| CORRECTIVE ACTION |
|
| A. Verify that the fryer is plugged in | |
| A. No power to fryer. |
| and that the circuit breaker is not |
|
|
| tripped. |
| B. Damaged computer wiring | B. Call FASC. | |
| harness. |
|
|
| C. Failed Computer | C. | Call FASC. |
No display on the |
| D. If any component in the power | |
|
| supply system (including the | |
computer. |
|
| |
|
| transformer and interface board) | |
|
|
| |
| D. Power supply component or |
| fail, power will not be supplied |
|
| to the computer and it will not | |
| interface board has failed. |
| |
|
| function. Determining which | |
|
|
| |
|
|
| component has failed is beyond |
|
|
| the scope of operator |
|
|
| troubleshooting. Call FASC. |
| A. Drain valve not fully closed. | A. | Press the ON/OFF switch off, |
|
|
| close the drain valve(s) |
|
|
| completely, then press the |
|
|
| ON/OFF switch on. |
| B. Gas valve is not turned on. | B. | Turn the gas valve knob to the |
|
| ON position. | |
|
|
| |
|
| C. | Verify that any |
| C. Manual gas shut off valve closed. |
| shut off valve is open. Verify |
|
| that gas main cut off valve is | |
|
|
| |
Fryer does not heat. |
|
| open. |
D. Improperly connected quick- | D. | Verify that the | |
| disconnect fitting on gas line. |
| fitting on the flexible gas line is |
|
| firmly connected to the fryer. | |
|
|
| |
|
| E. | Verify that combustion air |
|
|
| blower is running. If not, call |
| E. Obstructed or failed combustion |
| FASC for service. If combustion |
| air blower. |
| air blower is functional, clean |
|
|
| and adjust per instructions in |
|
|
| Chapter 5 of this manual. |
| F. Damaged computer wiring | F. | Call FASC. |
| harness or connector. |
|
|
Fryer is operating |
|
|
|
normally, but | Dirty or obstructed combustion air |
| Clean and adjust per instructions |
recovery is slow | blower. |
| in Chapter 5 of this manual. |
when cooking. |
|
|
|