Siemens Electrical Lean Switch Technical Specifications of the ELS TP40, Attachments

Models: Electrical Lean Switch

1 97
Download 97 pages 10.2 Kb
Page 81
Image 81

Technical Specifications

7.1Technical Specifications of the ELS TP40

Attachments

Attachment of DTEs or Network

2 x RJ-45 jacks with MDI-X pinning

Components over Twisted Pair

10/100 Mbps (half/full duplex)

Attachment of Industrial Ethernet FC

2 x insulation piercing contacts with

TP cables

MDI-X 10/100 Mbps (half/full duplex)

Connector for power supply

1 x 3-pin plug-in terminal block

 

Electrical Data

Power Supply

24 V dc supply

 

(18 to 32 V dc)

 

safety extra-low voltage (SELV)

Power loss at DC 24 V

3.6 W

 

 

Current consumption at rated voltage

150 mA

Overcurrent protection at input

PTC resettable fuse (0.6 A / 60 V)

 

Permitted Cable Lengths

Attachment over Industrial Ethernet FC

100 m standard cable

TP cables

85 m trailing cable

 

85 m marine cable

TP Connection

When using the FC Outlet RJ-45, the

 

following cable lengths are permitted:

 

100 m for standard cable

 

85 m for trailing cable

 

85 m for marine cable

Note

The number of ELS switches connected influences the frame propagation time. When a frame passes through the ELS, it is delayed by the Store&Forward func- tion of the switch.

-with a frame length of 64 bytes by approximately 10 s

-with a frame length of 1500 bytes by approximately 130 s

This means that the more ELS switches the frame passes through, the longer the propagation time.

Aging Time

5 minutes

Industrial Ethernet

81

A5E00152007-03

Page 81
Image 81
Siemens Electrical Lean Switch Technical Specifications of the ELS TP40, Attachments, Electrical Data