Installation and Maintenance

Installation in a 19" Cubicle

To install in the 19" cubicle, you require the two securing brackets supplied. You can achieve the 19'' width

with 3 ELS devices

Follow the steps outlined below:

1.First screw the ELS switches to the supplied mounting plates at the rear.

2.Fit two of the supplied brackets to the sides

3.Secure the devices using the brackets in the 19" cubicle.

Wall Mounting

To install an ELS on a wall, follow the steps below:

1.Fit the supplied mounting brackets on the sides of the ELS.

2.Secure the device to the wall using the brackets and fittings suitable for the wall in question.

3.Using one of the brackets or the PE screw terminal, connect the device with protective earth with as low a resistance as possible.

Note

The module must be secured to the wall so that the mounting can carry at least four times the weight of the module.

Grounding

19" Cubicle

Please note that the ELS must be grounded with low resistance via the two holding brackets. It is also possible to ground the device suing the PE screw terminal on the terminal block.

Mounting on a DIN Rail

The device is grounded either via the DIN rail or the PE screw terminal on the terminal block.