2.The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than ½ psi (3.5 kPa).
2.1.3 Electrical Grounding Requirements
All electrically operated appliances must be grounded in accordance with all applicable national and local codes, and, where applicable, CE codes. In the absence of local codes, the appliance must be grounded in accordance with National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.2, as applicable. All units (cord connected or permanently connected) should be connected to a grounded power supply system. A wiring diagram is located on the inside of the fryer door. Refer to the rating plate on the inside of the fryer door for proper voltages.
DANGER
This appliance is equipped with a special (grounding) plug for your protection against electrical shock, and must be plugged directly into a properly grounded re- ceptacle. Do not cut, remove, or otherwise bypass the grounding prong on this plug!
DANGER
This appliance requires electrical power for operation. Place the gas control valve in the OFF position in case of a prolonged power outage. Do not attempt to operate this appliance during a power outage.
2.1.4 Australian Requirements
To be installed in accordance with AS 5601 / AG 601, local authority, gas, electricity, and any other relevant statutory regulations.
2.2Caster/Leg Installation
Depending upon the specific configuration ordered, your fryer may have been shipped without installed casters or legs. DO NOT INSTALL THIS APPLIANCE WITHOUT CASTERS OR
LEGS. If the appliance requires the installation of casters or legs, install them in accordance with the instructions included in your accessory package.
On an appliance with casters; the installation shall be made with a connector that complies with the Standard for Moveable Gas Appliances, ANSI Z21.69 • CSA 6.16, and a quick disconnect device that complies with the Standard for
• CSA 6.9.
2.3Pre-Connection Preparations
DANGER
DO NOT connect this appliance to the gas supply before completing each step in this section.