Frymaster Protector Series operation manual Danger

Models: Protector Series

1 66
Download 66 pages 44.54 Kb
Page 50
Image 50
Figure 12

Manual background DANGER

NEVER attempt to clear a clogged drain valve from the front of the valve! Hot oil will rush out creating the potential for severe burns.

Manual background DANGER

DO NOT hammer on the drain valve with the cleanout rod or other objects. Damage to the ball inside will result in leaks and will void the Frymaster warranty.

6.After the oil has drained from the frypot, rotate the filter handle towards the I” to start the pump and begin the filtering process. There may be a slight delay before the pump activates (see Figure 11).

Pull filter handle forward to activate pump.

Figure 11

7.The filter pump draws the oil through the filter medium and circulates it back up to and through the frypot during a 5-minute process called polishing. Polishing cleans the oil by trapping solid particles in the filter medium.

8.After the oil is filtered (about 5 minutes), close the drain valve and allow the fryer to refill. Let the filter pump run 10 to 12 seconds after the oil begins to bubble. Turn the filter off.

The computer displays FILTER DONE alternating with YES NO.

9. Press the 9 (1) button when filtration is finished (see Figure 12).

The computer displays OFF.

Figure 12

 

Manual background WARNING

The filter pump is equipped with a manual reset switch in case the filter motor overheats or an electrical fault occurs. If this switch trips, turn off power to the filter system and allow the pump motor to cool 20 minutes before attempting to reset the switch (see photo below).

Filter Pump Reset Switch

5-6