7.2.4 Auto Top-Off Problems

PROBLEM

PROBABLE CAUSES

CORRECTIVE ACTION

 

 

A. Paper/screen needs changed or

 

 

cleaned.

 

 

B. If using filter paper

Filter pump runs,

 

configuration, verify that filter

A. Paper/screen clogged.

screen is in bottom of pan with

but oil return is very

B. Improperly installed filter pan

paper on top of screen.

slow and bubbling

components.

 

oil occurs.

C. Attempting to filter with oil that

Verify that O-rings are present

 

is not hot enough.

and in good condition on filter

 

 

pan connection fitting.

 

 

C. In order to properly filter, the oil

 

 

should be at or near 350ºF

 

 

(177ºC).

Filter pump runs

Blockage in filter pan suction tube.

The blockage may be caused by

Test: Close the drain valve and pull

sediment buildup. Use a thin,

but oil does not

the filter pan out from the fryer.

flexible wire to remove the

return to frypot and

Activate the pump. If bubbling oil

blockage. If the blockage cannot be

there is no bubbling

occurs, there is a blockage in the

removed, call FASC.

oil.

filter pan suction tube.

 

 

 

7.2.4 Auto Top-Off Problems

 

Problem

Probable Causes

 

A. Fryer temperature too low.

Frypots won’t top

B. Temperature of oil too cold.

C. Supply line out of JIB.

off.

D. CM7 not readdressed after ATO

 

switch was switched on.

 

 

7.2.5 Basket Lift Problems

Corrective Action

A. Fryer temperature must be at least 300°F (149°C).

B. Ensure that oil is above 70°F (21°C).

C.Ensure supply line is in JIB.

D.Switch all CM7 computers off and then on again to readdress system.

If problem persists call your FASC.

PROBLEM

PROBABLE CAUSES

CORRECTIVE ACTION

Basket lift

 

Apply a light coating of

Basket lift rods need lubrication.

Lubriplateor similar lightweight

movement is jerky

white grease to the rod and

and/or noisy.

 

 

bushings.

 

 

7-5