Problem | Probable Causes |
| Corrective Action |
|
| ||
Heat indicator off |
|
|
|
|
|
|
|
upon initial startup. | Failed computer, damaged wiring |
|
|
|
|
|
|
Display shows hi or |
| Call your FASC. |
|
|
| ||
harness or connector. |
|
|
|
| |||
hot with alarm |
|
|
|
|
|
| |
|
|
|
|
|
|
| |
sounding. |
|
|
|
|
|
|
|
Computer locks up. |
|
| Turn the computer OFF and then |
|
| ||
Computer error. |
| ON again. If problem persists, |
|
| |||
|
|
| contact your FASC. |
|
|
| |
7.2.3 Filtration Problems |
|
|
|
|
|
| |
|
|
|
|
|
| ||
PROBLEM | PROBABLE CAUSES |
| CORRECTIVE ACTION |
|
| ||
| A. Power cord is not plugged in or | A. Verify that the power cord is fully |
| ||||
| circuit breaker is tripped. |
| plugged in. Is so, verify that |
|
| ||
|
|
| circuit breaker is not tripped. |
|
| ||
|
|
| B. If the motor is too hot to touch |
| |||
|
|
| for more than a few seconds, the |
| |||
| B. Pump motor has overheated |
| thermal | overload | switch | has |
|
| causing the thermal overload |
| probably | tripped. | Allow | the |
|
| switch to trip. |
| motor to cool at least 45 minutes |
| |||
|
|
| then press the Pump Reset |
| |||
|
|
| Switch. |
|
|
|
|
| C. Failed filter handle microswitch. | C. If the switch is loose, tighten the |
| ||||
| Test: If this is a |
| nuts and bolts holding it in place, |
| |||
Filter Pump won’t |
| ensuring that when the handle is |
| ||||
attempt to operate the pump using |
| placed in the ON position, the |
|
| |||
start. |
|
|
| ||||
a different handle. If the pump |
| lever on the microswitch is |
|
| |||
|
|
|
| ||||
OR | starts, the handle microswitch is |
| pressed firmly against the switch. |
| |||
either out of alignment or has |
|
|
|
|
|
| |
|
| If the switch has failed, call |
|
| |||
Pump stops during | failed. |
|
|
| |||
|
| FASC. |
|
|
|
| |
filtering. | When the handle is placed in the |
|
|
|
|
| |
|
|
|
|
|
| ||
|
|
|
|
|
|
| |
| ON position, the lever on the |
|
|
|
|
|
|
| microswitch should be firmly |
|
|
|
|
|
|
| pressed against the switch. If so, |
|
|
|
|
|
|
| the switch has failed. If not, the |
|
|
|
|
|
|
| switch is loose and/or misaligned. |
|
|
|
|
|
|
| D. Filter pump blockage. | D. Pump blockages are usually |
|
| |||
| Test: Close the drain valve and |
| caused by sediment |
| |||
|
| the pump due to improperly sized |
| ||||
| pull the filter pan out from the |
| or installed filter paper and failure |
| |||
| fryer. Activate the pump. If the |
| to use the crumb screen. Call |
|
| ||
| pump motor hums for a short time |
| FASC. |
|
|
|
|
| then stops, the probable cause is |
|
|
|
|
|
|
| blockage of the pump itself. |
|
|
|
|
|
|