Frymaster YSCFC24 Troubleshooting, Pilot Burner Malfunctions, Pilot will not ignite no, burner

Models: YSCFC24

1 40
Download 40 pages 54.68 Kb
Page 33
Image 33
CHAPTER 7: TROUBLESHOOTING

YSCFC24 SERIES FLATBOTTOM GAS FRYERS

CHAPTER 7: TROUBLESHOOTING

FACTORY APPROVAL MUST BE OBTAINED PRIOR TO ANY WARRANTY WORK BEING

DONE OR FRYMASTER CANNOT BE HELD RESPONSIBLE.

The following procedures must be performed by Factory Authorized Service Technicians, and are provided as an aid to expedite troubleshooting and repair of YSCFC24 Series frying systems.

7.1 PILOT BURNER MALFUNCTIONS

PROBLEM

CORRECTIVE ACTION

Pilot will not ignite; no

Ensure the combination gas valve is in PILOT position and that

evidence of gas at pilot

gas is available at the control valve (check quick-disconnect

burner.

and/or gas-line connections for proper connection).

 

 

Pilot burner ignites but will

Pilot flame may be adjusted incorrectly. Adjust flame to 1½"

not remain lit when gas

high by turning pilot flow adjustment screw.

knob is released.

 

 

 

Pilot burner ignites

1. Pilot flame may be adjusted too low, even though it

properly and burns

appears to be satisfactory. Re-adjust higher as described

properly, but goes out

earlier.

 

when the exhaust blower

2. Pilot flame may be adjusted too high and is on the verge

comes on.

of blowing out. Re-adjust lower.

 

 

7-1

Page 33
Image 33
Frymaster YSCFC24 Troubleshooting, Pilot Burner Malfunctions, Pilot will not ignite no, evidence of gas at pilot, burner