7.3 INDICATOR LIGHTS (cont.)
When turning the power switch "ON" and resetting the safety (reset) switch, check for the following:
LIGHT INDICATION |
| PROBABLE CAUSE | |
|
|
| |
GREEN LIGHT/POWER SWITCH IS | 1. | The drain valve is open. | |
"ON" | 2. The drain switch is defective. | ||
GREEN LIGHT/SAFETY (RESET) | |||
|
| ||
SWITCH IS "OFF" |
|
| |
GREEN LIGHT/CONTROL PANEL IS |
|
| |
"OFF" |
|
| |
RED LIGHT/CONTROL PANEL IS |
|
| |
"OFF" |
|
| |
GREEN LIGHT/POWER SWITCH IS | 1. | No power to fryer. | |
"OFF" | 2. | Fuse is blown. | |
GREEN LIGHT/SAFETY (RESET) | |||
|
| ||
SWITCH IS "OFF" |
|
| |
GREEN LIGHT/ CONTROL PANEL IS |
|
| |
"OFF" |
|
| |
RED LIGHT/CONTROL PANEL IS |
|
| |
"OFF" |
|
| |
|
|
|
CORRECTIVE ACTION
1.Ensure the drain valve is completely closed, and then turn the reset switch to "ON".
2.If the light on the reset switch does not turn on, contact a Factory Authorized Service Center for assistance.
1.Check power source, power cords and breaker. Ensure that electricity is available to the fryer.
2.Replace fuse. If fuse continues to blow, contact a Factory Authorized Service Center.
3.If fryer does not function after resetting the reset switch, contact a Factory Authorized Service Center for assistance.
7.4 THERMATRON CONTROLLER CALIBRATION
If the Thermatron controller requires adjustment, do the following:
1.Set Thermatron controller dial to the desired shortening temperature and wait for the shortening temperature to stabilize.
2.When shortening temperature reaches setpoint (heat light will go off), check the temperature with a
3.Loosen two knob setscrews and rotate the knob to the correct temperature setting on the Thermatron faceplate.
4.Check the temperature again with a
5.
Loosen two setscrews in dial (arrows) to recalibrate controller.