Device information

MSBLSB

7 6 5 4 3 2 1 0

Dynamic threshold circuit option

0 : Not provided

1 : Provided

ADF

0 : Not provided

1 : Provided

Flatbed/ADF

0 : Flatbed state

1 : ADF

Vertical/horizontal

0 : Portrait

1 : Landscape

Half>tone

0 : OFF

1 : ON

ADF cover

0 : Close

1 : Open

Job separate sheet detection (*1)

0 : Nonjob separate sheet

1 : Job separate sheet

Paper setting

0 : No paper in paper chute

1 : Paper in paper chute

*1 This bit is valid when it is specified in normal status response for the START command.

6

$ 54