6.4.5Operation error

This response indicates that the error related to operation specification program occurs.

Byte 1

Byte 2

Byte 3

CNT

RPS

TEXT

 

 

 

X©03￿

X©55￿

Detailed error information I

 

 

 

Detailed information I

Detailed information I gives details on errors in command/response transmission and reception to and from the host computer

MSBLSB

7 6 5 4 3 2 1 0

0 0

The dither pattern or the overlay pattern r pattern not registered was specified.

The bit or number of an undefined control register was specified.

An operation was specified for a nonexistent option.

Read area specification error (*1)

An undefined command was received.

Command sequence error

*1 Although standard paper size bit on control register 5 is on (Bit 7 takes ™1￿ and bit 6 takes ™0￿), the size specifying bits (bits 0 to 4) are not defined.

Control register contents do not change even if the above errors are detected.

6

$ 60

50FH5037E>02