6.4.5Operation error
This response indicates that the error related to operation specification program occurs.
Byte 1 | Byte 2 | Byte 3 |
CNT | RPS | TEXT |
|
|
|
X©03 | X©55 | Detailed error information I |
|
|
|
Detailed information I
Detailed information I gives details on errors in command/response transmission and reception to and from the host computer
MSBLSB
7 6 5 4 3 2 1 0
0 0
The dither pattern or the overlay pattern r pattern not registered was specified.
The bit or number of an undefined control register was specified.
An operation was specified for a nonexistent option.
Read area specification error (*1)
An undefined command was received.
Command sequence error
*1 Although standard paper size bit on control register 5 is on (Bit 7 takes ™1 and bit 6 takes ™0), the size specifying bits (bits 0 to 4) are not defined.
Control register contents do not change even if the above errors are detected.
6 | $ 60 | 50FH5037E>02 |