| Sequence 1 | t1 | Sequence 2 | Note 1 |
|
| Sequence 3 |
| t1 | Sequence 4 |
H | S | P S S | P S |
|
|
|
|
|
| S | P S |
RXD | T 0 1 0 0 0 | 0 0 0 B P T 0 0 1 0 1 0 1 | 0 B P |
|
|
|
|
|
| T | 1 1 1 1 1 1 1 1 B P |
L | B | B B | B |
|
|
|
|
|
| B | B |
|
|
|
|
|
|
|
|
|
|
| |
H |
|
| S | P S |
| S | P S S | P S S | P S S | P S |
|
TXD |
|
| T 1 | 1 1 1 1 1 1 1 B P |
| T 0 0 1 | 0 0 0 0 0 B P T 0 1 | 1 0 0 0 1 0 B P T 0 0 0 0 0 | 1 1 1 B P T 1 0 0 | 0 0 0 0 0 B P |
|
L |
|
| B | B |
| B | B B | B B | B B | B |
|
|
|
|
|
|
|
|
|
|
|
| |
H |
|
|
|
|
|
|
|
|
|
|
|
CTS |
|
|
|
| t2 |
|
|
|
| t2 |
|
L |
|
|
|
|
|
|
|
|
| ||
H |
|
|
|
|
|
|
|
|
|
|
|
RTS |
|
|
|
|
|
|
|
|
|
|
|
L |
|
|
|
|
|
|
|
|
|
|
|
H |
|
|
|
|
|
|
|
|
|
|
|
DTR |
|
|
|
|
|
|
|
|
|
|
|
L |
|
|
|
|
|
|
|
|
|
|
|
H |
|
|
|
|
|
|
|
|
|
|
|
DSR |
|
|
|
|
|
|
|
|
|
|
|
L |
|
|
|
|
|
|
|
|
|
|
|
t1: Less than 500 ms
t2: More than 1 byte
Sequence 1: The host computer send the READ command to the scanner.
X`02', `5A'
Sequence 2: ACK for the READ command is sent to the host computer.
X`FF'
Sequence 3: Response for the READ command (read complete) is sent to the scanner.
X`04', `46', `E0', `01'
Sequence 4: ACK for the read complete is sent to the scanner.
Note 1:
Expect issuing read complete, the RTS signal is inhibitory taking low level.
Figure 6.8 Read command sequence