(b)Image control register #1
LSB
7 | 6 |
| 5 | 4 | 3 |
| 2 | 1 | 0 |
|
|
| |||
0 |
|
|
|
|
|
|
|
|
|
| 0 |
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| Automatic separation specification (*1) | |||
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
| 0¥: | Based on the operator panel | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| specification (*3) |
|
|
|
|
|
|
|
|
|
|
| 1 0: | Automatic separation is not done. | |||
|
|
|
|
|
|
|
|
|
|
| 1 1: | Automatic separation |
Conversion mode specification
0¥¥: No operation
1 0 0: Not provided with white/black conversion.
Not provided with right/left conversion.
1 0 1: Not provided with white/black conversion.
Provided with right/left conversion.
1 1 0: Provided with white/black conversion. Not provided with right/left conversion.
1 1 1: Provided with white/black conversion. Provided with right/left conversion.
Subwindow specification (*2)
0 : Subwindow invalid
1 : Subwindow valid
Note:
Image control registers #1 to #3 must be sent in one sequence. One of automatic separation, image emphasis, outline extract, overlay can be specified.
*1 Halftone specification (control register #2) is invalid in the automatic separation mode. However halftone processing (dither or error diffusion) for photo area follows control register #19, and the dither pattern follows control register #2.
*2 The subwindow control register is valid when the subwindow is valid.
*3 When automatic separation specification is based on operator panel, the bit 7 of image control register #2 and the bit 3 of image control register #3 must be set to ©0.
X©00 is set when the power is turned on or when the initial state is specified by the CLEAR command.