(i)Control register #19

LSB

7 6 5 4 3 2 1 0

0 0

Read density step specification

0:

Eight steps

(Control register #1 is valid.)

1:

256 steps

(Control register #20 is valid.)

Halftone processing method specification

0:Dithering

1:Error diffusion

d pattern number specification

(*1)

0 0 0

: Normal

 

 

 

 

 

 

 

 

 

 

0 0 1

: Soft

 

 

 

 

 

 

 

0 1 0

: Sharp

 

 

 

 

 

 

 

 

 

0 1 1

:

 

 

 

 

 

1 0 0

Three types (0 to 2) if the

 

 

1 0 1

built>in patterns are valid.

 

1 1 0

Eight types (0 to 7) if

 

1 1 1

downloading is enabled.

 

Downloaded or built>in d patterns

0:The patterns built into the device are valid.

1:The downloaded patterns are valid.

*1 If the built>in patterns are valid, 0 to 2 ( ©000￿ to ©010￿ ) can be selected.

X©00￿ is set whenever the power is turned on or when the initial state is specified by the CLEAR command.

6

$ 18

50FH5037E>02