(i)Control register #19
LSB
7 6 5 4 3 2 1 0
0 0
Read density step specification
0: | Eight steps | (Control register #1 is valid.) |
1: | 256 steps | (Control register #20 is valid.) |
Halftone processing method specification
0:Dithering
1:Error diffusion
d pattern number specification | (*1) | |||||
0 0 0 | : Normal |
|
|
|
|
|
|
|
|
|
| ||
0 0 1 | : Soft |
|
|
| ||
|
|
|
| |||
0 1 0 | : Sharp |
|
|
|
|
|
|
|
|
| |||
0 1 1 | : |
|
|
|
|
|
1 0 0 | Three types (0 to 2) if the |
| ||||
| ||||||
1 0 1 | built>in patterns are valid. |
| ||||
1 1 0 | Eight types (0 to 7) if |
| ||||
1 1 1 | downloading is enabled. |
|
Downloaded or built>in d patterns
0:The patterns built into the device are valid.
1:The downloaded patterns are valid.
*1 If the built>in patterns are valid, 0 to 2 ( ©000 to ©010 ) can be selected.
X©00 is set whenever the power is turned on or when the initial state is specified by the CLEAR command.
6 | $ 18 | 50FH5037E>02 |