(c)Control register #2

X©00￿ is set when the power is turned on or when a CLEAR command is issued for initialization

MSBLSB

7

6

5

4

3

2

1

0

0

Jam detection when scanning

0 : Executed

1 : Not executed

Specifies halftone

0¥ : Set from the operator panel

1 0 : Not dithered

1 1 : Dithered or Error Diffusion (*2)

Dither pattern (*1)

0 0 0

0 0 1

0 1 0

0 1 1

1 0 0

1 0 1

1 1 0

1 1 1

Built>in/Download

0 : Built>in

1 : Download

*1 f When the built>in pattern is used, the density information shown in the control register #1 is valid.

f4 patterns (000 to 011) are valid when the built>in pattern is selected.

fWhen the download pattern is used, the density information shown in Control register #1 is invalid.

f8 patterns (000 to 111) is valid when the download pattern is selected.

*2 Dithered or Error diffusion are selected by control register #19.

6

$ 10

50FH5037E>02