(b)Control register #1

X©00￿ is set when the power is turned on or when a CLEAR command is issued for initialization

MSBLSB

7

6

5

4

3

2

1

0

0

Density

 

 

 

0 0¥¥¥

: Set from the operator panel

0 1 0 0 0

:

Light

 

 

0 1 0 0 1

:

 

Darken more

0 1 0 1 0

:

Somewhat light

and more

0 1 0 1 1

:

 

 

0 1 1 0 0

:

Normal

*3

0 1 1 0 1

:

 

 

0 1 1 1 0

:

Somewhat dark

 

0 1 1 1 1

:

Dark

 

1¥¥¥¥

:

Automatic (*1)

 

Linedrawing/photograph

0¥ : Specified from the operator panel

1 0 : Linedrawing (*2)

11 : Photograph (*2)

*1 This function is valid for image processing circuit (IPC ¬) option.

When the IPC ¬ option is installed and these bits indicate 1xxxx, the scanner applies the DTC function, and the function of the image control register and subwindow control register are not operated.

*2 The scanning speed of ADF (sheets/min) in Linedrawing mode is different from that of Photograph mode. See Appendix B for more information.

*3 When the control registor #19, bit 0 is ©0￿, 8 typs density are sellectable by the control registor #1, bit 3 to 0.

And when the control registor #19, bit 0 is ©1￿, 256 typs density are sellectable by the control registor #20.