5.3Data Transfer
Scanning video data is transferred to the host computer through video data signal lines V0 to V7 in parallel synchronized with VCL.
5.3.1Transfer sequence
Scanning is performed as shown in Figure 5.2, and the scanning data is assigned to the video data signal as shown in Figure 5.3. The scanning data is sent to the host computer in order of scanning.
Main scanning
Subscanning
Figure 5.2 Scanning direction
5 | $ 4 | 50FH5037E>02 |