CHAPTER 4 CONTROL INTERFACE

4.1Connection Specifications

4.2Control Interface Signals

4.3Driver/Receiver

4.4Timing

This chapter describes the control interface between the host computer and the scanner. For details of the interface, refer to the EIA RS>232C standard.

4.1Connection Specifications

 

 

 

 

 

 

Specification

 

 

 

 

Remarks

 

 

 

 

 

 

 

 

 

 

 

 

Transmission system

 

Half>duplex

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Synchronization

 

Start>stop

 

 

 

 

 

system

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Data length

 

8 bits

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Stop bit

 

1 bit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Data check

 

Odd parity check

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D0 D1 D2 D3 D4 D5 D6 D7 P

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Start bit

Stop bit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Data transfer rate

 

1200, 2400, 4800, 9600 bps

 

 

 

 

Set by

 

 

 

 

 

 

 

 

 

 

 

EEPROM on

 

 

 

 

 

 

 

 

 

 

 

Interface PCA

 

 

 

 

 

 

 

 

 

 

 

Default:

 

 

 

 

 

 

 

 

 

 

 

4800 bps.

 

 

 

 

 

 

 

 

 

 

 

 

Maximum connection

 

5 m (16 ft.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Standard

 

EIA RS>232C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50FH5037E>02

4

$ 1