Furuno 1724C, 1734C manual Data Boxes Setup, Data box menu

Models: 1724C 1734C

1 247
Download 247 pages 40.41 Kb
Page 191
Image 191

7. CUSTOMIZING YOUR UNIT

7.5Data Boxes Setup

You may select the data to show in the data boxes for the plotter, radar and sounder displays. Six boxes may be displayed in case of small size data box and two for large size data box.

1.Display the radar, plotter or sounder display, whichever you want to set.

2.Press the MENU key to open the main menu.

3.Press one of the following sets of soft keys depending on the display selected at step 1. Plotter mode: PLOTTER SETUP, D. BOX

Radar mode: RADAR DISPLAY SETUP, D. BOX

Sounder mode: SOUNDER MENU, D. BOX

XDATABOX SIZE

SMALL

 

POSITION

ON

WAYPOINT

OFF

COG

ON

SOG

ON

STW

OFF

BEARING

OFF

RANGE

OFF

TIME TO GO

OFF

ETA

OFF

TEMPERATURE

OFF

DEPTH

OFF

TRIP LOG

ON

DATE

OFF

TIME

OFF

WIND

OFF

HEADING

OFF

AIR TEMPERATURE OFF

AIR PRESSURE

OFF

DATA BOX

EDIT

RETURN

Data box menu

4.Use the Cursor pad to select an item, then press the EDIT soft key.

5.Select ON or OFF as desired.

6.Press the ENTER soft key or the ENTER knob to register your selection. Six items may be set to ON for small data boxes; two for large data boxes.

7.Repeat steps 4-6 to turn other items on or off.

8.Press the MENU key to close the menu.

7-22

Page 191
Image 191
Furuno 1724C, 1734C manual Data Boxes Setup, Data box menu