7. CUSTOMIZING YOUR UNIT

7.9.3Sounding range, zoom range, bottom lock range

This paragraph shows you how to set custom ranges for basic range, zoom range (marker and bottom zoom) and bottom lock range. All default basic ranges are restored whenever the unit of depth measurement is changed. Therefore, change the depth unit before changing the basic ranges.

1.Show the sounder display, then press the MENU key to open the main menu.

2.Press the SOUNDER RANGE SETUP soft key to show the SOUNDER RANGE SETUP menu.

RANGE 1

RANGE

SETUP

15 ft

 

RANGE 2

EDIT

30 ft

 

RANGE 3

 

60 ft

 

RANGE 4

 

120 ft

 

RANGE 5

 

200 ft

 

RANGE 6

 

400 ft

 

RANGE 7

 

1000 ft

 

RANGE 8

 

4000 ft

RETURN

ZOOM RANGE

 

10 ft

 

BOTTOM LOCK RANGE

 

10 ft

 

Sounder range setup menu

3.Select the range to change, then press the EDIT soft key.

4.Rotate the Cursor pad or ENTER knob to set range desired, then press the RETURN soft key. For basic range, set depth from lowest to highest; a range cannot be higher than its succeeding neighbor.

5.Press the MENU key to finish.

Default basic ranges

Range 1

Range2

Range 3

Range 4

Range 5

Range 6

Range 7

 

Range 8

 

 

 

 

 

 

 

ETR-6/10N

 

ETR-30N

5 m

10 m

20 m

40 m

80 m

150 m

300 m

1200 m

 

1500 m

 

 

 

 

 

 

 

 

 

 

15 ft

30 ft

60 ft

120 ft

200 ft

400 ft

1000 ft

4000 ft

 

4500 ft

 

 

 

 

 

 

 

 

 

 

3 fa

5 fa

10 fa

20 fa

40 fa

80 fa

150 fa

650 fa

 

900 fa

 

 

 

 

 

 

 

 

 

 

3 P/B

5 P/B

10 P/B

30 P/B

50 P/B

100 P/B

200 P/B

700 P/B

 

900 P/B

 

 

 

 

 

 

 

 

 

 

Zoom range and bottom-lock ranges

Item

Settings

Default Setting

 

 

 

Zoom Range

2 m – 120 m, 7 ft – 400 ft,

10 m, 30 ft, 10 fa, 10 P/B

 

1 fa – 60 fa, 1 P/B – 700 P/B

 

Bottom-lock

3 or 6 m, 10 or 20 ft, 2 or 3

6 m, 20 ft, 3 fa, 3 P/B

Range

fa, 2 or 3 P/B

 