4. VIDEO SOUNDER OPERATION

4.1.2Description of sounder displays

Single-frequency display

 

 

 

 

Display mode

 

 

Variable Range Marker (white)

 

 

 

Depth scale

Soft keys

 

Minute marker

Time

 

 

 

 

Zero line

 

 

0'30"

0

SOUNDER

Icons

 

S

 

 

SINGLE

 

M

 

 

 

 

 

I

 

 

 

(alarm, battery,

F

 

 

 

 

simulation)

 

 

 

SHIFT

50

 

52

50

 

 

 

 

 

Color bar

 

Fish

 

 

AUTO/

 

40

Cross-hair

D. BOX

 

echo

 

 

 

 

 

 

 

Temp.

 

 

cursor

FREQ

 

 

 

 

scale

30

 

 

100

LF /HF

(orange)

 

 

 

 

 

 

 

 

Water

 

 

 

 

DISPLY

 

 

 

 

MODE

temp.

 

 

 

 

 

 

 

150

 

graph

 

 

 

 

Water

 

 

 

 

 

 

 

 

 

 

 

114

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

temp.

 

 

 

 

 

 

 

 

 

 

 

200

 

 

 

 

display

 

 

 

 

LF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tx frequency

 

Bottom echo

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Depth

Indications on the single frequency display

Note: The water temperature display requires an appropriate water temperature sensor. It can be turned on or off with TEMPERATURE GRAPH on the SOUNDER MENU.

Selecting transmission frequency

The single frequency display shows either the LF (low frequency) picture or HF (high frequency) picture. To select transmission frequency, press the FREQ LF/HF soft key. “LF” or “HF” is highlighted on its key label with each press of the key.

Dual-frequency display

The dual-frequency display provides both LF and HF pictures. This display is useful for comparing the same picture with two different sounding frequencies.

LF picture

The sounder uses ultrasonic pulses to detect bottom conditions. The lower the frequency of the pulse, the wider the detection area. Therefore, the low

 

0.0

LF

HF

Dual-frequency display

4-2

Page 131
Image 131
Furuno 1734C manual Description of sounder displays, Single-frequency display, Indications on the single frequency display