CANCEL ALL TARGETS
§ °YES
NO
Cancel all targets window

2. RADAR OPERATION

2.25.3 Displaying target number (ARP, TTM)

Target number can be shown for ARP and TTM targets as below.

ARP

Target

Number

.250/

.125nm

319.9

° T

TARGET

SP

 

 

 

H-UP

TRAIL

TLL

OUTPUT

01

ACQ

TARGET

INFO

RETURN

+359.9° R 0.240nm

ARP target number

1.Press the MENU key.

2.Press the ARP SETUP soft key.

3.Select TARGET ID NUMBER.

4.Press the EDIT soft key.

5.Select ON or OFF as appropriate.

6.Press the ENTER soft key.

7.Press the MENU key to close the menu.

2.25.4 Terminating tracking of ARP targets

When ten targets have been acquired, no more acquisition occurs unless targets are cancelled. If you need to acquire additional targets, you must first cancel one or more individual targets, or all targets, using one of the procedures below.

Terminating tracking of selected targets

1.Place the cursor on the target to terminate tracking.

2.Press the CLEAR key to terminate tracking and erase the target.

Terminating tracking of all targets

1. Press the MENU key followed by the ARP SETUP soft key.

2. Select CANCEL ALL TARGETS.

3. Press the EDIT soft key.

4. Select YES.

5.Press the ENTER soft key.

6.Press the RETURN soft key followed by the MENU key to close the menu.

2-31