3.4Checking Magnetron Heater Voltage

Note: This confirmation/adjustment should only be performed by a qualified service technician.

Magnetron heater voltage is formed on the PTU (1833C-BB)/MD (1823C-BB/1933C-BB/ 1943C-BB/1953C-BB) Board of the antenna unit, and preadjusted at the factory. Therefore no adjustment is required. However, check magnetron heater voltage for confirmation as follows:

1.Open the antenna unit.

2.Turn on the power. Do not transmit the radar.

3.Connect a multimeter, set to 10 VDC range, on the MD (1823C-BB), PTU (1833C-BB) or RTB (1933C-BB/1943C-BB/1953C-BB) Board in the antenna unit, referring to the table below.

4.Confirm that the multimeter indication is as shown in the table below.

 

MODEL1823C-BB

MODEL1833C-BB

MODEL1933C-BB/

 

1943C-BB/1953C-BB

 

 

 

 

 

 

 

Check point

TP804#6 (+) and #4 (-)

TP802#4 (+) and #6 (-) on

J825#4 and #6 (GND) on

on MD Board

PTU Board

RTB Board

 

 

 

 

 

Multimeter indication

7.9 to 8.1 V

7.4 to 7.6 V

7.4 to 7.6 V

 

 

 

 

Adjustment point

VR801 on MD Board

R106 on PTU Board

VR801 on MD Board

 

 

 

 

3.5Navigation Data Source

The NAV SOURCE SETTINGS menu mainly selects the source of nav data. For navigator other than the FURUNO GP-310B/320B, speed averaging and local time offset (to use local time instead of UTC time) are also available from this menu.

1.Press the [MENU] key followed by E: SYSTEM CONFIGURATION, B: NAV OPTION

and A: NAV SOURCE SETTINGS soft keys to show the NAV SETUP menu.

POSITION SOURCE

ALL

NAV

SETUP

SPEED AVERAGING*

0060second (s)

 

LOCAL TIME OFFSET*

+00:00

 

TEMP CALIBRATION

+00 F

A EDIT

DEPTH CALIBRATION

+00ft

 

 

 

E RETURN

* For GPS receiver other than GP-310B/320B.

Nav setup menu

3-11

Page 55
Image 55
Furuno 1953C-BB, GD-1900C-BB, 1943C-BB, 1933C-BB Checking Magnetron Heater Voltage, Navigation Data Source, Nav setup menu