Mounting procedure

Flush mounting

Follow the procedure below to mount the control unit on a panel with accessories FP03-10001.

1.Prepare a cutout in the mounting location, referring to the outline drawing at the end of this manual.

2.Set the control unit to the cutout.

3.Attach the mounting plate to the control unit with four screws M4 x 10 from the rear side.

4.Screw four wing bolts into wing nuts.

5.Fasten the control unit to the mounting location with four wing bolts and wing nuts assembled at step 4.

(A)

80±1

280±1

20.5

A: Thickness of panel

10<A<20 mm

Flush mounting of display unit

6. Attach hard cover to protect the control unit.

How to remove the hard cover

Place your thumbs at the locations shown with circles in the illustration at right, and then lift the cover while pressing it with your thumbs.